Appendix A — Specifications
138 CK31 Handheld Computer User’s Manual
Near-Far Range Area Imager Reading Distances
This section contains minimum and typical reading distances for
the near far range area imager.
Minimum Reading Distances
Minimum reading distances are measured in the dark (0 lux).
1D Symbologies Minimum Reading Distances With 0.889 cm (0.350 in) Setback
Symbology Density Minimum Distance Maximum Distance
Code 39 0.10 mm (3.8 mils) 18.889 cm (7.437 in) 31.111 cm (12.248 in)
0.25 mm (10 mils) 18.889 cm (7.437 in) 68.111 cm (26.815 in)
0.5 mm (20 mils) 19.889 cm (7.830 in) 109.111 cm (42.957 in)
1 mm (40 mils) 40.889 cm (16.098 in) 219.111 cm (86.264 in)
1.3 mm (51 mils) 100.889 cm (39.720 in) 309.111 cm (121.697 in)
2.54 mm (100 mils) 130.889 cm (51.531 in) 429.111 cm (168.941 in)
EAN 100% 0.33 mm 22.889 cm (9.011 in) 99.111 cm (39.020 in)